EPA Method 25B Determination Of Total Gaseous Organic Concentration Using A Nondispersive Infrared Analyzer
ID: |
89567C23D52B4BB099F22446A185C377 |
文件大小(MB): |
0.01 |
页数: |
4 |
文件格式: |
|
日期: |
2000-2-12 |
购买: |
文本摘录(文本识别可能有误,但文件阅览显示及打印正常,pdf文件可进行文字搜索定位):
1264,METHOD 25B - DETERMINATION OF TOTAL GASEOUS ORGANIC,CONCENTRATION USING A NONDISPERSIVE INFRARED ANALYZER,NOTE: This method does not include all of the,specifications (e.g., equipment and supplies) and procedures,(e.g., sampling) essential to its performance. Some,material is incorporated by reference from other methods in,this part. Therefore, to obtain reliable results, persons,using this method should have a thorough knowledge of at,least the following additional test methods: Method 1,Method 6C, and Method 25A.,1.0 Scope and Application.,1.1 Analytes.,Analyte CAS No. Sensitivity,Total Organic,Compounds,N/A < 2% of span,1.2 Applicability. This method is applicable for the,determination of total gaseous organic concentration of,vapors consisting primarily of alkanes. Other organic,materials may be measured using the general procedure in,this method, the appropriate calibration gas, and an,analyzer set to the appropriate absorption band.,1.3 Data Quality Objectives. Adherence to the,requirements of this method will enhance the quality of the,data obtained from air pollutant sampling methods.,2.0 Summary of Method.,1265,A gas sample is extracted from the source through a,heated sample line, if necessary, and glass fiber filter to,a nondispersive infrared analyzer (NDIR). Results are,reported as volume concentration equivalents of the,calibration gas or as carbon equivalents.,3.0 Definitions. Same as Method 25A, Section 3.0.,4.0 Interferences. [Reserved],5.0 Safety.,5.1 Disclaimer. This method may involve hazardous,materials, operations, and equipment. This test method may,not address all of the safety problems associated with its,use. It is the responsibility of the user of this test,method to establish appropriate safety and health practices,and determine the applicability of regulatory limitations,prior to performing this test method. The analyzer users,manual should be consulted for specific precautions to be,taken with regard to the analytical procedure.,5.2 Explosive Atmosphere. This method is often,applied in highly explosive areas. Caution and care should,be exercised in choice of equipment and installation.,6.0 Equipment and Supplies.,Same as Method 25A, Section 6.0, with the exception of,the following:,1266,6.1 Organic Concentration Analyzer. A nondispersive,infrared analyzer designed to measure alkane organics and,capable of meeting or exceeding the specifications in this,method.,7.0 Reagents and Standards.,Same as Method 25A, Section 7.1. No fuel gas is,required for an NDIR.,8.0 Sample Collection, Preservation, Storage, and,Transport.,Same as Method 25A, Section 8.0.,9.0 Quality Control.,Same as Method 25A, Section 9.0.,10.0 Calibration and Standardization.,Same as Method 25A, Section 10.0.,11.0 Analytical Procedure.,The sample collection and analysis are concurrent for,this method (see Section 8.0).,12.0 Calculations and Data Analysis.,Same as Method 25A, Section 12.0.,13.0 Method Performance. [Reserved],14.0 Pollution Prevention. [Reserved],15.0 Waste Management. [Reserved],16.0 References.,Same as Method 25A, Section 16.0.,1267,17.0 Tables, Diagrams, Flowcharts, and Validation Data.,[Reserved]……
……